Cirrus Perspective
by Garmin – Cockpit Reference Guide for the SR20/SR22/SR22T
190-00821-06 Rev. A
94
Annunciations & Alerts
Flight
InstrumentsEIS
Nav/Com/
XPDR/AudioAFCSGPS Nav
Flight
PlanningProcedures
Hazard
Avoidance
Additional
Features
Abnormal
Operation
Annun/
AlertsAppendixIndex
GMA 347 MESSAGE ADVISORIES (CONT.)
Message Comments
MANIFEST
– GMA1 software
mismatch, communication halted.
The audio panel has incorrect software installed.
The Perspective
system should be serviced.
GMA1 SERVICE
– GMA1 needs
service. Return unit for repair.
The audio panel self-test has detected a problem.
Certain audio functions may still be available,
and the audio panel may still be usable. The
Perspective
system should be serviced when
possible.
GIA 63W MESSAGE ADVISORIES
Message Comments
GIA1 CONFIG
– GIA1 config error.
Config service req’d.
The GIA1 and/or GIA2 configuration settings do
not match backup configuration memory. The
Perspective
system should be serviced.
GIA2 CONFIG
– GIA2 config error.
Config service req’d.
GIA1 CONFIG
– GIA1 audio config
error. Config service req’d.
The GIA1 and/or GIA2 have an error in the audio
configuration. The Perspective
system should
be serviced.
GIA2 CONFIG
– GIA2 audio config
error. Config service req’d.
GIA1 COOLING
– GIA1
temperature too low.
The GIA1 and/or GIA2 temperature is too low
to operate correctly. Allow units to warm up to
operating temperature.
GIA2 COOLING
– GIA2
temperature too low.
GIA1 COOLING
– GIA1 over
temperature.
The GIA1 and/or GIA2 temperature is too high.
If problem persists, the Perspective
system
should be serviced.
GIA2 COOLING
– GIA2 over
temperature.
GIA1 SERVICE
– GIA1 needs
service. Return the unit for repair.
The GIA1 and/or GIA2 self-test has detected a
problem in the unit. The Perspective
system
should be serviced.
GIA2 SERVICE
– GIA2 needs
service. Return the unit for repair.