System Annunciation Comment
Display is not receiving valid heading input from AHRS.
Display is not receiving valid transponder information.
Other Various Red X Indications
A red ‘X’ through any other display field, such as engine instrumentation
fields, indicates that the field is not receiving valid data.
Message Advisory Alerts
Alerts Window Message Audio Alert
PFD FAN FAILThe cooling fan for the PFD is inoperative.
NoneMFD FAN FAILThe cooling fan for the MFD is inoperative.
GIA FAN FAILThe cooling fan for the GIAs is inoperative.
MFD & PFD Message Advisories
Message Comments
DATA LOST
– Pilot stored data was
lost. Recheck settings.
The pilot profile data was lost. System reverts to default pilot profile and settings.
The pilot may reconfigure the MFD & PFD with preferred settings, if desired.
XTALK ERROR
A flight display
crosstalk error has occurred.
The MFD and PFD are not communicating with each other. The G1000 system
should be serviced.
PFD1 SERVICE
– PFD1 needs service.
Return unit for repair.
The PFD and/or MFD self-test has detected a problem. The G1000 system should
be serviced.
MFD1 SERVICE
– MFD1 needs
service. Return unit for repair.
MANIFEST
– PFD1 software
mismatch. Communication halted.
The PFD and/or MFD has incorrect software installed. The G1000 system should
be serviced.
MANIFEST
– MFD1 software
mismatch. Communication halted.
PFD1 CONFIG
– PFD1 configuration
error. Config service req’d.
The PFD configuration settings do not match backup configuration memory. The
G1000 system should be serviced.
MFD1 CONFIG
– MFD1 configuration
error. Config service req’d.
The MFD configuration settings do not match backup configuration memory. The
G1000 system should be serviced.
SW MISMATCH
– GDU software
version mismatch. Xtalk is off.
The MFD and PFD have different software versions installed. The G1000 system
should be serviced.