Garmin G1000 Cockpit Reference Guide for the Piper PA32
12-11
SECTION 12 – ANNUNCIATIONS
& ALERTS
GMA 1347 Message Advisories
Message Comments
GMA1 FAIL
– GMA1 is inoperative. The audio panel self-test has detected a failure. The audio panel is unavailable.
The G1000 system should be serviced.
GMA1 CONFIG
GMA1 configuration
error. Config service req’d.
The audio panel configuration settings do not match backup configuration
memory. The G1000 system should be serviced.
MANIFEST – GMA1 software
mismatch. Communication halted.
The audio panel has incorrect software installed. The G1000 system should be
serviced.
GMA1 SERVICE
– GMA1 needs
service. Return unit for repair.
The audio panel self-test has detected a problem in the unit. Certain audio functions
may still be available, and the audio panel may still be usable. The G1000 system
should be serviced when possible.
GIA 63W Message Advisories
Message Comments
GIA1 CONFIG
– GIA1 configuration
error. Config service req’d.
The GIA1 and/or GIA2 configuration settings do not match backup configuration
memory. The G1000 system should be serviced.
GIA2 CONFIG
– GIA2 configuration
error. Config service req’d.
GIA1 CONFIG
– GIA1 audio config
error. Config service req’d.
The GIA1 and/or GIA2 have an error in the audio configuration. The G1000
system should be serviced.
GIA2 CONFIG
– GIA2 audio config
error. Config service req’d.
GIA1 COOLING
– GIA1 temperature
too low.
The GIA1 and/or GIA2 temperature is too low to operate correctly. Allow units to
warm up to operating temperature.
GIA2 COOLING
– GIA2 temperature
too low.
GIA1 COOLING
– GIA1 over
temperature.
The GIA1 and/or GIA2 temperature is too high. If problem persists, the G1000
system should be serviced.
GIA2 COOLING
– GIA2 over
temperature.
GIA1 SERVICE
– GIA1 needs service.
Return the unit for repair.
The GIA1 and/or GIA2 self-test has detected a problem in the unit. The G1000
system should be serviced.
GIA2 SERVICE
– GIA2 needs service.
Return the unit for repair.