Garmin Software Version 0321.23 Instrukcja Obsługi Strona 123

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 122
G1000 System Maintenance Manual – Diamond DA40/40F Page 4-31
190-00545-01 Revision G
4.11.2 PFD/MFD Power Interrupt Function Check (SW v0321.22 ONLY)
The MFD and PFD power interrupt backup capacitors must be checked every aircraft annual.
1. Remove the MFD and PFD displays following the instructions shown in Section 6.1.
2. Review the TSO label on each display. Check the MOD Status block against Table 4-5:
Table 4-5. Power Interrupt Category A (200mS) Mod Status
Unit Unit Part Number
Long Term
Power Interrupt
Category B (200 mS)*
Mod Status
GDU 1040
011-00972-00 2
011-00972-03 1
GDU 1042 011-01080-00 1
GDU 1044 011-01078-01 1
*Per RTCA DO-160D Section 16.
a) If display meets or exceeds the minimum MOD status required as specified in Table 4-5, then no
further action is required. Reinstall the display according to Section 6.1.
b) If one or both displays do not meet the specified MOD status, then the following procedure must
be performed.
Category B Long Term Power Interrupt Annual Inspection Procedure
1. Before beginning the Category B Long Term Power Interrupt Annual Inspection Procedure, the
test software “GDU Backup Cap Test Software (006-B0380-15)” must be downloaded from the
Garmin website:
Access the Dealer Resource Center portion of the Garmin website (www.garmin.com
).
From the Technical Resource list, click on the “GDU Backup Cap Test Software
(006-B0380-15)” link.
Extract the files onto a blank SD card.
2. Remove the Supplemental Data Card from the lower slot of the GDU before loading any
software.
NOTE
Supplemental Data Cards left inserted can become corrupt, making them unusable.
Replacing corrupt cards is not covered under warranty.
3. Insert the SD card containing the test software into the top slot of the MFD.
NOTE
Loading “GDU Backup Cap Test Software (006-B0380-15)” to the GDU temporarily
changes the GDU software version to v7.10. It is required to return the system to the
currently approved system software version and configuration following the Long Term
Power Interrupt Test.